Checklist · Daily Plant Prestarts

Boom Lift (Knuckle / Telescopic EWP) Pre-Start Checklist

Daily pre-start inspection for self-propelled and trailer-mounted boom lifts covering the boom, jib, turntable, platform, harness anchor points, tilt alarm and emergency lowering. Completed by the operator before each shift.

43 checklist items · Last reviewed

Checklist Items

ItemPass / YesFail / No
MACHINE & OPERATOR DETAILS
Date
Plant ID / Serial Number
Make, Model & Working Height
Operator Name
High Risk Work Licence Number (WP required for boom length 11 m or more)
Hour Meter Reading
POWER & FLUIDS
Fuel level or battery charge adequate for shiftPassFail
Engine oil and coolant levels adequate (engine units)PassFail
Hydraulic oil level adequatePassFail
No hydraulic, fuel or battery leaksPassFail
CHASSIS & TURNTABLE
Tyres / wheels: no damage, wheel nuts securePassFail
Outriggers / stabilisers (if fitted): pads and interlocks operatePassFail
Turntable bearing and bolts: no visible play or damagePassFail
Counterweight secure, no damagePassFail
Turntable lock / slew pin released for operationPassFail
BOOM & JIB
Boom sections and knuckle: no cracks, dents or weld damagePassFail
Jib and rotator: no damage, operate smoothlyPassFail
Wear pads, chains and cables (where visible) serviceablePassFail
Hydraulic hoses: no chafing, leaks or damagePassFail
Pins and retainers all in placePassFail
PLATFORM / BASKET
Platform floor, rails and mid-rails undamagedPassFail
Entry gate / chain self-closes and latchesPassFail
Harness anchor points: present, undamaged, labelledPassFail
Rated load plate (persons and kg) legiblePassFail
Platform controls labelled, guarded and return to neutralPassFail
Secondary guarding / anti-entrapment device operational (if fitted)PassFail
SAFETY DEVICES & FUNCTION TESTS
Ground controls: all functions tested from ground stationPassFail
Platform controls: all functions tested, foot switch / enable operatesPassFail
Emergency stops at ground and platform functionalPassFail
Tilt alarm / cut-out operationalPassFail
Platform overload sensing operational (if fitted)PassFail
Emergency / auxiliary lowering system testedPassFail
Travel alarm, horn and beacon operationalPassFail
Manual and decals on machine and legiblePassFail
SITE CHECKS
Ground firm and level; no pits, trenches or soft spotsYesNo
Overhead hazards and powerlines identifiedYesNo
Rescue plan in place for stranded or injured operatorYesNo
Operator and occupants wearing harness with short lanyard clipped to anchorYesNo
DEFECTS & SIGN-OFF
Defects found (describe or write "None")
Defects reported to supervisorYesNo
Machine fit for operationYesNo
Operator Signature
Supervisor Signature